FLOOR / CEILING Assemblies – Concrete
Sound Tests 
DSA Engineers
Direct fix under 8" concrete no topping FIIC 51 STC 71
FULL REPORT
REV: 08-21-04
FILE NAME: test_fcs1_dswa_fiic_51_raw_full_report.pdf
Direct fix under 8" concrete, ceramic tile FIIC 70 STC 71
FULL REPORT
REV: 08-21-04
FILE NAME: test_fcs2_dswa_fiic_70_tile_with_matt_full_report.pdf
Direct fix under 8" concrete, 1/4" regupol matt, ceramic tile FIIC 69 STC 71
FULL REPORT
REV: 08-21-04
FILE NAME: test_fcs3_dswa_fiic_69_tile_with_matt_full_report.pdf
Direct fix under 8" concrete, hard wood flooring with 1/16" vapor barrier mat FIIC 74 STC 71
FULL REPORT
REV: 08-21-04
FILE NAME: test_fcs4_dswa_fiic_74_hw_full_report.pdf
Direct fix under 8" concrete, hard wood flooring FIIC 72 STC 71
FULL REPORT
REV: 08-21-04
FILE NAME: test_fcs5_dswa_fiic_72_hw_no_pad_full_report.pdf
Direct fix under 8" concrete, Cushioned Vinyl FIIC 74 STC 71
FULL REPORT
REV: 08-21-04
FILE NAME: test_fcs6_dswa_fiic_72_vinyl_full_report.pdf
Direct fix under 8" concrete, Carpet with pad FIIC 87 STC 71
FULL REPORT
REV: 08-21-04
FILE NAME: test_fcs7_dswa_fiic_87_carp_w_pad_full_report.pdf
Direct fix under 8" concrete, carpet no pad FIIC 84 STC 71
FULL REPORT
REV: 08-21-04
FILE NAME: test_fcs8_dswa_fiic_84_carp_no_pad_full_report.pdf
DIRECT FIX TO STEEL AND CONCRETE FIIC 65 FSTC 69
REV: 01-31-05
FILE NAME: test_fc_steel_fstc69_fiic65.pdf
USA PATENT NUMBER 6,267,347
RSIC UL FIRE RATINGS