WALL Assemblies - Steel
STC 58
RSIC-1® Acoustic Assembly
DIRECT FIX TO STEEL WALL FRAME
CONSTRUCTION
* 1 layer 5/8" Gypsum Board
* 3.5" Steel Stud at 24" oc
* R-19 Insulation 5.5"
* RSIC-1® 48" oc.
* Drywall Furring Channel at 24" oc
* 1 layer 5/8" Gypsum Board
UL U419, U423
STC 61
RSIC-1® Acoustic Assembly
DIRECT FIX TO STEEL STUD
CONSTRUCTION
* 1 layer 5/8" Gypsum Board
* 1 layer 1/8" 1 lb (UL Listed) MLV
* 3.5" Steel Stud at 24" oc
* R-19 Insulation 5.5"
* RSIC-1® 48" oc.
* Drywall Furring Channel at 24" oc
* 1 layer 5/8" Gypsum Board
UL U419, U423
STC 61
RSIC-1® Acoustic Assembly
DIRECT FIX TO STEEL STUD
CONSTRUCTION
* 1 layer 5/8" Gypsum Board
* 1 layer 1/4" 2 lb MLV
* 3.5" Steel Stud at 24" oc
* R-19 Insulation 5.5"
* RSIC-1® 48" oc.
* Drywall Furring Channel at 24" oc
* 1 layer 5/8" Gypsum Board
UL U419, U423
STC 60
RSIC-1® Acoustic Assembly
DIRECT FIX TO STEEL SHAFT WALL STUD
CONSTRUCTION
* layer 1" Shaft Liner Gypsum Board
* 4" C-H Steel Stud at 24" oc
* R-19 Fiberglass Batt Insulation 5.5"
* RSIC-1 spaced at 24" oc.
* Drywall Furring Channel at 24" oc
* 2 layers 5/8" Type "X" Gypsum Board
* UL U415
STC 61
RSIC-1® Acoustic Assembly
DIRECT FIX TO STEEL WALL FRAME
CONSTRUCTION
* 1 layer 5/8" Gypsum Board
* 3.5" Steel Stud at 24" oc
* R-19 Insulation 5.5"
* RSIC-1® 48" oc.
* Drywall Furring Channel at 24" oc
* 2 layers 5/8" Gypsum Board
* UL U419, U423
STC 64
RSIC-1® Acoustic Assembly
DIRECT FIX TO STEEL WALL FRAME
CONSTRUCTION
* 2 layers 5/8" Gypsum Board
* 3.5" Steel Stud at 24" oc
* R-19 Insulation 5.5"
* RSIC-1® 48" oc.
* Drywall Furring Channel at 16" oc
* 2 layers 5/8" Gypsum Board
* UL U419, U423
STC 56
RSIC-1® Acoustic Assembly
DIRECT FIX TO STEEL STUD
CONSTRUCTION
* 1 layer 5/8" Gypsum Board
* 2.5" Steel Stud at 16" oc
* R-11 Insulation 3.5"
* RSIC-1® 48" oc.
* Drywall Furring Channel at 24" oc
* 1 layer 5/8" Gypsum Board
STC 60
RSIC-1® Acoustic Assembly
DIRECT FIX TO STEEL STUD
CONSTRUCTION
* 2 layers 5/8" Gypsum Board
* 2.5" Steel Stud at 16" oc
* R-11 Insulation 3.5"
* RSIC-1® 48" oc.
* Drywall Furring Channel at 24" oc
* 1 layer 5/8" Gypsum Board
STC 62
RSIC-1® Acoustic Assembly
DIRECT FIX TO STEEL STUD
CONSTRUCTION
* 2 layers 5/8" Gypsum Board
* 2.5" Steel Stud at 16" oc
* R-11 Insulation 3.5"
* RSIC-1® 48" oc.
* Drywall Furring Channel at 24" oc
* 2 layers 5/8" Gypsum Board
WALL/CEILING JUNCTION - FLOOR/CEILING JUNCTION
Corner Junction Steel Studs Walls
Wall to Floor Junction Steel Studs
Wall Intersection (interrupted) Steel Studs
Wall to Ceiling/Floor Junction Parallel to Joist, Steel Studs
Wall to Ceiling/Floor Junction Perpendicular to Joist, Steel Studs
Wall to Ceiling Junction Perpendicular to Joist, Steel Studs